Burkert – Type 8098 – FLOWave SAW Flowmeter
จุดเด่นของ Type 8098
- No obstacles inside the measuring tube, compact, lightweight and low energy consumption
- Conforms to hygienic requirements, CIP/SIP compatible
- Ideal for liquids with low or no conductivity
- Digital communication, parameterisation via Communicator, display
- Optional: ATEX/IECEx certification, II 3G/D
รายละเอียดเพิ่มเติม
type 8098
FLOWave SAW flowmeter
The Type 8098 flowmeter is part of the FLOWave product range. It is based on SAW (Surface Acoustic Waves) technology and is mainly designed for applications with the highest hygienic demands. This is achieved by using:
- suitable stainless steel materials
- a measuring tube free of any wetted parts except for the actual tube
- the ideal outer hygienic design.
DOWNLOAD CATALOG (ดาวน์โหลดแคตตาล็อก)
BURKERT TYPE 8098 สามารถใช้ได้ร่วมกับ
-
Burkert - Type 8802 - Continuous control Valve Systems Overview (Type ELEMENT)
-
Burkert - Type 8619 multiCELL Multi Channel and Multi Function Transmitter / Controller
-
Burkert - Type 8647 - AirLINE SP Electro-Pneumatic Automation System
-
Burkert - Type ME43 - Fieldbus Gateway
General Technical Data
Product Properties |
|
Material
|
Please make sure the device materials are compatible with the fluid you are using.
|
Sensor housing (Non-Wetted Parts)
|
For sensor with process connection ≤ DN 50/2″: stainless steel 304/1.4301 / For sensor with process connection > DN 50/2″: stainless steel 316L/1.4435
|
Measurement tube and process connection (Wetted Parts)
|
Stainless steel 316L/1.4435 with low delta ferrite content
|
Measurement tube (inner surface)
|
Ra < 0.8 μm (30 μin.) or Ra < 0.4 μm (15 μin.) (electro-polished) according to ISO 4288 |
Measurement tube (outer surface) |
Ra < 1.6 μm (excluding welding seams) according to ISO 4288
|
Housing |
Ra < 1.6 μm according to ISO 428
|
Dimensions
|
Detailed information can be found in chapter “4. Dimensions” on page 20.
|
Volume flow rate measurement measuring range
|
0…1.7 m3/h up to 0…200 m3/h
|
Density measurement measuring range
|
0.8…1.3 g/cm3 (inactive by default, selectable upon request)
|
Mass flow rate measurement measuring range |
0…1 360 kg/h up to 0…260 000 kg/h (inactive by default, selectable upon request)
|
Temperature measurement measuring range |
– 20…+ 140 °C (- 4…+ 284 °F)
|
Special function
|
Active by default, deselectable upon request: ATF: acoustic transmission factor & DF: differentiation factor / Inactive by default, selectable upon request: Concentration
|
Electrical Data |
|
Operating voltage | • 12…35 V DC filtered and regulated • Tolerance: ± 10 % • Connection to main supply: permanent (through external SELV (Safety Extra Low Voltage) and LPS (Limited Power Source) power supply) |
Power source (not supplied)
|
Limited power source according to UL/EN 60950-1 standards or limited energy circuit accord- ing to UL/EN 61010-1 §9.4
|
DC reverse polarity protection | Yes |
Voltage supply cable for cable gland
|
0.2…1.5 mm2 cross-section / In nickel plated brass: Cable with maximum operating temperature greater than + 80 °C (+ 176 °F) OR 5…14 mm diameter, shielded cable / In stainless steel: Cable with maximum operating temperature greater than + 80 °C (+ 176 °F) OR 6…12 mm diameter, shielded cable |
Voltage supply cable for 5 pin M12 male fixed connec- tor (A-coded) | Cable with maximum operating temperature greater than + 80 °C (+ 176 °F) / 3…6.5 mm diameter, shielded cable, / 0.75 mm2 cross-section to connect to 5 pin M12 female connector (A-coded, not supplied) |
Voltage supply cable for 4 pin M12 female fixed con- nector (D-coded) | Cable with maximum operating temperature greater than + 80 °C (+ 176 °F) / 5e / CAT-5 min. category, 100 m max. length, shielded conductor with minimum STP |
Medium Data |
|
Fluid
|
Non-dangerous liquids complying with article 4, §1 of 2014/68/EU directive between 1000 m/s and 2000 m/s for process connection DN 08, 3⁄8″ and 1⁄2″ or between 800 m/s and 2300 m/s for process connection DN ≥ 15 or ≥ 3⁄4″ |
Fluid temperature | – 20…+ 110 °C (- 4…+ 230 °F). The maximum fluid temperature can be restricted by the ambient operating temperature OR Max. conditions for sterilisation process: up to + 140 °C (+ 284 °F) (+ 130 °C (+ 266 °F) for ATEX/IECEx variant) for max. 60 min OR Maximum temperature gradient: 10 °C/s (18 °F/s) (measured by the integrated sensor on the device) |
Process/Port Connection & Communication |
|
DIN 32676 series A / DIN 11850
|
Clamp: DN 08, DN 15, DN 25, DN 40, DN 50, DN 65 and DN 80
|
DIN 32676 series B / ISO 1127 |
Clamp: DN 08, DN 15, DN 25, DN 40, DN 50, DN 65 and DN 80
|
DIN 32676 series C / ASME BPE
|
Clamp: 3⁄8″, 1⁄2″, 3⁄4″, 1″, 11⁄2″, 2″, 21⁄2″ and 3″
|
DIN 11864-2 form A series A / DIN 11850
|
Aseptic collar flange (BF)4.): DN 15, DN 25, DN 40 and DN 50
|
DIN 11864-2 form A series B / ISO 1127
|
Aseptic collar flange (BF)4.): DN 08, DN 15, DN 25, DN 40 and DN 50
|
DIN 11864-2 form A series C / ASME BPE
|
Aseptic collar flange (BF)4.): 1⁄2″, 3⁄4″, 1″, 11⁄2″ and 2″
|
DIN 11864-3 form A series A / DIN 11850
|
Aseptic collar clamp (BKS)4.): DN 15, DN 25, DN 40 and DN 50
|
DIN 11864-3 form A series B / ISO 1127
|
Aseptic collar clamp (BKS)4.): DN 08, DN 15, DN 25, DN 40 and DN 50
|
DIN 11864-3 form A series C / ASME BPE
|
Aseptic collar clamp (BKS)4.): 1⁄2″, 3⁄4″, 1″, 11⁄2″ and 2″
|
SMS 3017 / SMS 3008
|
Clamp: DN 25, DN 40 and DN 50
|
DIN 11851 series A / DIN 11850 | Thread: DN 65 and DN 80 |
Device status
|
LED light ring according to NAMUR NE 107
|
Approvals and Certificates |
|
CE directive
|
The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable).
|
Pressure equipment directive |
Complying with Article 4, Paragraph 1 of 2014/68/EU directive
|
Certification
|
EHEDG (Type EL CLASS I) / 3A (28-06) / UL-Listed for USA and Canada OR ATEX/IECEx (On request) |
Certificate | FDA declaration of conformity / Inspection certificate 3.1 / Certification of compliance ASME BPE / Calibration certificate / On request: USP class VI Declaration, ECR1935/2004 declaration, CRN 0C21751 declaration, Test report 2.2, Certification of conformity for the surface quality DIN 4762, EN ISO 4287, EN ISO 4288, Certification of conformity for passivation and electro-polishing processes, and MTBF (Mean Time Between Failures) manufacturer declaration |
Environment and Installation |
|
Ambient temperature – Operation |
Depends on the fluid temperature. Detailed information can be found in chapter “5.1. Medium temperature” on page 25.
|
Ambient temperature – Storage |
– 20…+ 70 °C (- 4…+ 158 °F)
|
Relative air humidity
|
≤85%, without condensation
|
Height above sea level | Max. 2000 m |
Operating condition |
Continuous
|
Equipment mobility | Fixed device |
Application range |
Indoor and outdoor (protect the device against electromagnetic interference, ultraviolet rays and, when installed outdoors, against the effects of climatic conditions)
|
Degree of protection
|
IP65, IP67 (according to IEC/EN 60529), NEMA 4X (according to NEMA250), if the product is wired and if the cable glands are tightened and the covers are screwed tight. Unused cable glands must be sealed with the stopper gaskets provided (mounted upon delivery of the prod- uct). An unused M12 fixed connector must be protected by the screwed plug. |
Installation category
|
Category I according to UL/EN 61010-1
|
Pollution degree | Degree 2 according to UL/EN 61010-1 |
*For selecting thecorrect product please refer to the technical data, images and notes for proper use according to the data sheet, or contact Flu-Tech directly.
สอบถามข้อมูลเพิ่มเติม ติดต่อเรา :
สินค้าที่เกี่ยวข้อง
จุดเด่นของ Type 8647
- Easy diagnostics by LC display
- Integration in Siemens PCS7 possible
- Safety-related shut-off of valves possible
- Combination of fieldbus, pilot valves and I/O modules
- Direct connection to the I/O systems SIMATIC ET 200SP and SIMATIC ET 200SP HA
จุดเด่นของ Type 8644
- High flow rate
- High flexibility
- Compact design
- Innovative fieldbus interface
- Combination of Fieldbus, pilot valves and I/O modules
จุดเด่นของ BURKERT - TYPE 8694
- Contact-free position sensor
- Integrated control air routing
- Start-up by automatic TUNE-function
- Compact, robust stainless steel design
- AS-Interface, IO-Link or Bürkert System bus (büS)
จุดเด่นของ Type 8653
- Easy diagnostics via LC display
- Optimised for installation in the field (IP65/67)
- Process reliability through pneumatic functions
- Fieldbus interface CANopen, IO-Link or büS (Bürkert System Bus)
จุดเด่นของ Type 3320
- Rapid flow shut off
- Many diagnostic functions
- Fail-safe position by energy storage
- Weather and impact resistant design
- Designed according to hygienic demands
จุดเด่นของ Type 8686
- Version for ATEX / IECEx
- Compact stainless steel design
- Fieldbus AS-Interface (optional)
- Coloured illuminated status display
- Contactless valve position registration
จุดเด่นของ Type 8681
- Coloured status display
- AS-Interface, IO-Link, büS/CANopen
- Manual override operative with closed housing
- Universal attachment for hygienic process valves
- Contactless position measurement system with 3 switching points (Teach-In function)
จุดเด่นของ Type ME63
- Up to 128 input and 128 output variables can be transmitted
- Integrated central configuration management for easy device replacement
- Connection of up to eight end devices or junction box modules, connection of up to 126 CANopen participants
- Simpler integration of Bürkert devices in the process control level through individually configurable device description files
- Gateway for Industrial Ethernet standards, incl. OPC UA, for use in environments requiring a high degree of protection